O'Neal, D. L.; Boecker, C. L.; Murphy, W. E.; Notman, J. R. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1986)The objectives of this study included: (1) development of classes of heat pumps, (2) evaluation and selection of a suitable heat pump design model, (3) characterization of suitable baseline heat pump designs, (4) selection ...
-
An Analysis of Efficiency Improvements in Residential Sized Heat Pumps and Central Air Conditioners O'Neal, D. L.; Boecker, C. L.; Penson, S. B. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1986)This report summarizes: (1) the performance improvements possible for central air conditioners and heat pumps using conventional design improvements, (2) the development of a methodology for estimating the seasonal ...
-
O'Neal, D. L.; Murphy, W. E. (Lawrence Berkeley Laboratory, University of California, 1985)The objectives of this study included: (1) development of classes of heat pumps, (2) evaluation and selection of a suitable heat pump design model, (3) characterization of suitable baseline heat pump designs, (4) selection ...
-
O'Neal, D. L.; Penson, S. B. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1988)
-
Chen, L.; Kissock, J. K.; Haberl, J. S.; Heneghan, T.; Ruch, D.; O'Neal, D. L.; Katipamula, S.; Hinchey, S.; Wang, J.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)The analysis effort during the first year of the Texas LoanSTAR Monitoring and Analysis Program has emphasized selection and development of baseline analysis techniques to cover the range of buildings expected in the ...
-
O'Neal, D. L.; Reddy, T. A.; Sucher, B. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1996)The National Energy Modeling System (NEMS) is a comprehensive, computer-based, energy-economy modeling system developed and maintained by the Department of Energy's Energy Information Administration (EIA). NEMS forecasts ...
-
Bryant, J. A.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)In support of the Texas LoanSTAR Energy Conservation Program, the Texas A&M University Monitoring and Analysis Program (MAP) calibration facility has been performing relative humidity calibrations for transducers being ...
-
Murphy, W. E.; Turner, W. D.; O'Neal, D. L.; Bolander, J. N.; Seshan, S. (Energy Systems Laboratory (http://esl.tamu.edu), 1985-05)In 1983, Texas Governor Mark White initiated an energy cost containment program for the largest state agencies. The Energy Management Group of the Mechanical Engineering Department at Texas A&M University was called ...
-
Katipamula, S.; O'Neal, D. L.; Farad, M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1986)The energy use of the Travis Building at Austin, Texas was analyzed using the DOE 2.1B building energy simulation program. An analysis was made for the building as specified in the building plans and as operated by the ...
-
Katipamula, S.; O'Neal, D. L.; Somasundaram, S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1987)A series of tests were performed to assesses the dehumidifying performance of residential central air conditioners (CACs). The performance studies were based on factors such as: (i) dynamic performance (ii) the ASHRAE ...
-
O'Neal, D. L.; Anand, N. K.; Peterson, K. T.; Schleising, S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1988)The objectives of this research were to: (1) characterize the reverse cycle defrost of the air-to-air heat pump and (2) examine the effect of different expansion devices on the performance of the heat pump during ...
-
Watt, J. B.; O'Neal, D. L.; Haberl, J. S. (Texas A&M University (http://www.tamu.edu); Energy Systems Laboratory (http://esl.tamu.edu), 1998)This paper presents results of a survey of the literature and identifies the most common degraded conditions associated with low-tonnage air conditioners. Other laboratory studies as well as marketed diagnostic systems ...
-
Medina, M. A.; Turner, W. D.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)This paper presents simulated performance of insulation/radiant barrier systems under different Texas climates. A transient heat and mass transfer model which predicts thermal performance of residential attics (Medina, ...
-
Bryant, J. A.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)Thermal energy consumption in buildings with chilled or hot water distribution systems is often monitored through the use of some type of flow metering device. These flowmeters can be fixed types, such as venturis or ...
-
O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where ...
-
Medina, M. A.; O'Neal, D. L.; Turner, W. D. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)Results of side-by-side radiant barrier experiments using two identical 144 ft2 (nominal) test houses are presented. The test houses responded very similarly to weather variations prior to the retrofit. The temperatures ...
-
Farzad, M.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1986)The energy use of the warehouse facility at the Human Services Center Complex in Austin, Texas was analyzed using the DOE-2.1B building energy simulation program. An analysis was made for each building as specified in ...
-
Farzad, M.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1986)The energy use and peak load requirements of the addition to Records Storage Building in Austin, Texas were analyzed using the DOE 2.1B building energy simulation program. An analysis was made for the building as specified ...
-
Farzad, M.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1986)The energy use of the Supreme Court and Attorney General buildings in Austin, Texas was analyzed using the D0E-2.1B building energy simulation program. An analysis was made for each building as specified in the building ...
-
Katipamula, S.; O'Neal, D. L. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1986)